Window insulation film

Window insulation film is a plastic film which can be applied to glass windows to reduce heat transfer. There are two types in common use designed to reduce heat flow via radiation and convection respectively.

Solar control film

This works by reflecting the infra-red component of solar energy (often 700W/sq M) and absorbing the UV component. Some films are also silvered or tinted to reduce visible light.

Typical absorption for a silvered film is 65% for visible and infra red with 99% for UV. This type of film sticks directly onto the glass.

Convection control film

A film is attached to the window frame to trap a pocket of air between the glass and the film, creating a double-glazed system with an insulating gap of still air. Thermal conductivity of still air is 0.024 W/m/K and much lower than that of glass (0.96 W/m/K).[1] Factors which limit the performance of a double glazed window are gap width, convection within the cavity and radiative heat transfer across the gap which is largely independent of its width.

Optimal gap width depends on the temperature difference imposed across the gap. A European standard (EN 673) uses 20 °C difference between the inside and outside temperature which results in an optimal simulated gap width of about 17 mm for a standard double glazed window. A US standard (NFRC) uses a 39 °C difference which yields a smaller optimal gap width of about 13 mm. Using the European standard a window with an ideal gap of 17 mm has a simulated U-Value of about 2.8 W/m2/K, a window with a much smaller gap of 6 mm has a U-value of about 3.3 W/m2/K, while a single glazed window has a U-value of about 5.5 W/m2/K.[2] (see also insulated glazing).

Typical window insulation film kit of plastic shrink film (folded-up) and a roll of double-sided tape

One commonly used film is a heat-shrink plastic which is attached to the window frame using double-sided pressure-sensitive tape. A hair dryer is used to remove creases and improve optical clarity.

Reduced heat flow also helps prevent condensation [3][4][5] which is triggered when the temperature of the inside surface falls below the dew point. Assuming an outside temperature of 0 °C with wind velocity 15 mph and inside temperature 20 °C condensation occurs at only 30%RH relative humidity with a single-glazed system compared with 60%RH for a double-glazed system.[6] Condensation also transfers additional heat, which can be significant.

Applications

"Low-E" glass was introduced to the North American residential building market in the 1980s by a collaboration between Rob Hammon, now with BIRAenergy, and Wade Martin, a windshield glass manufacturer.[7]

Solar control film is an effective way to control excessive sunshine during the summer months.

Convection control film is often used in winter when the outgoing heat flow is more important, especially for single-glazed windows where the temperature difference is often sufficient to cause condensation.

See also

References

  1. Thermal conductivity of common materials Engineering toolbox
  2. Optimal gap width for double and triple glazing systems
  3. Condensation on Inside Window Surfaces CANADIAN BUILDING DIGEST, Originally published April 1960, A. G. Wilson
  4. Questions about windows and condensation National Fenestration Rating Council
  5. Strategies to Prevent Condensation in Buildings Eduardo de Oliveira Fernandes, Vítor Leal and Francisco Craveiro IDMEC and DEMEGI, Faculty of Engineering, University of Porto Porto
  6. Condensation Potential Chart RLC Engineering, LLC.
  7. http://www.usglassmag.com/USGlass/2002/0208/LowEGrowth.html
This article is issued from Wikipedia. The text is licensed under Creative Commons - Attribution - Sharealike. Additional terms may apply for the media files.